EAST BAY - Homeowners aren't the only ones who need to be concerned about carbon monoxide poisoning. The "silent killer" can collect within, alongside, or behind a boat in minutes in a variety of ways.
Carbon monoxide is a potentially deadly gas produced any time a carbon-based fuel, such as gasoline, propane, charcoal, or oil, burns. Sources on your boat include gasoline engines, generators, cooking ranges, and space and water heaters. Cold or poorly tuned engines produce more carbon monoxide than warm, properly tuned engines.
Carbon monoxide is colorless, odorless and tasteless and mixes evenly with the air. It enters your bloodstream through the lungs and displaces the oxygen your body needs. Early symptoms of carbon monoxide poisoning irritated eyes, headache, nausea, weakness, and dizziness are often confused with seasickness or intoxication. Prolonged exposure to low concentrations or very short exposure to high concentrations can lead to death.
Each year, boaters are injured or killed by carbon monoxide. Most incidents occur on older boats and within the cabin or other enclosed areas. Exhaust leaks, the leading cause of death by carbon monoxide, can allow the gas to migrate throughout the boat and into enclosed areas. New areas of concern are the rear deck near the swim platform with the generator or engines running and teak surfing or dragging behind a slow-moving boat. Regular maintenance and proper boat operation can reduce the risk of injury from carbon monoxide.
Here are some ways you can avoid carbon monoxide poisoning:
* Avoid swimming near or under the back deck or swim platform. Carbon monoxide from exhaust pipes of inboard engines, outboard engines and generators build up inside and outside the boat in areas near exhaust vents. Stay away from these exhaust vent areas and do not swim in these areas when the motor or generator is operating.
* Avoid teak surfing, dragging and water-skiing within 20 feet of a moving watercraft.
* Don't block exhaust outlets, which can cause carbon monoxide to accumulate in the cabin and cockpit area even when hatches, windows, portholes, and doors are closed.
* Your boat should be a minimum of 20 feet from the nearest boat that is running a generator or engine. Exhaust from another vessel that is docked, beached, or anchored alongside your boat can emit poisonous carbon monoxide gas into the cabin and cockpit of your boat.
* Exercise caution with slow speeds or idling, which can cause carbon monoxide gas to accumulate in the cabin, cockpit, bridge, and aft deck, even in an open area. A tailwind (force of wind entering from aft section of the motorboat) can also increase accumulation.
* Also be careful of the "station wagon effect," or backdrafting, which can cause carbon monoxide to accumulate inside the cabin, cockpit, and bridge when operating the boat at a high bow angle, with improper or heavy loading or if there is an opening which draws in exhaust. This effect can also cause carbon monoxide to accumulate inside the cabin, cockpit, aft deck, and bridge when protective coverings are used and the boat is underway.
* Educate family and friends about carbon monoxide so they are aware of what the early poisoning signs are.
* If your boat has rear-vented generator exhaust, check with the boat manufacturer for possible recall or reroute the exhaust to a safe area.
* Assign an adult to watch when anyone is swimming or playing in the water.
* Schedule regular engine and exhaust system maintenance inspections by experienced and trained technicians.
* Do not confuse carbon monoxide poisoning with seasickness, intoxication, or heat stress. If someone on board complains of irritated eyes, headache, nausea, weakness, or dizziness, immediately move the person to fresh air, investigate the cause and take corrective action. Seek medical attention, if necessary.
* Install a carbon monoxide detector in each accommodation space on your boat. Check detectors before each trip to be sure they are functioning properly. If the detector goes off, take it seriously.
Do not operate your vessel without doing the following at least annually:
* Replace exhaust hoses if any evidence of cracking, charring or deterioration is found.
* Inspect each water pump impeller and the water pump housing, and replace if worn. Make sure cooling systems are in proper working condition to prevent overheating and burn through the exhaust system. (Refer to the engine and generator manuals for further information.)
* Inspect each of the metallic exhaust components for cracking, rusting, leaking or loosening. Pay particular attention to the cylinder head, exhaust manifold, water injection elbow and the threaded adapter nipple between the manifold and the elbow.
* Clean, inspect, and confirm proper operation of the generator cooling water anti-siphon valve (if equipped).
This annual checklist must be performed by a qualified marine technician.
Do not operate the boat without doing the following before each trip:
* Educate all passengers about carbon monoxide poisoning.
* Make sure all exhaust clamps are in place and secure.
* Look for exhaust leaking from exhaust system components, indicated by rust and/or black streaking, water leaks, or corroded or cracked fittings.
* Inspect rubber exhaust hoses for burned or cracked sections. All rubber hoses should be pliable and free of kinks.
* Confirm that water flows from the exhaust outlet when the engines and generator are started.
* Listen for any change in exhaust sound that could indicate an exhaust component failure.
* Test the operation of each carbon monoxide detector by pressing the test button. Make sure the battery is installed properly and is in good condition. Never remove the battery unless replacing it with a new battery.
Information adapted from the Utah Division of Parks and Recreation and U.S. Department of Interior carbon monoxide brochure.
|